Key Features
Class 100 / ISO Class 5 cleanroom packed and double bagged
High EMI/RFI immunity rating
Ultra-stable CVD sensing technology
Low internal volume (0.9cm³)
Markets & Applications
Machine Automation
High-Purity Gas Delivery Systems
Gas Sticks
Process gas analyzers
Electrical Termination
M12 Hirschmann® 993-172-100
Output Signal
4-20 mA (2-wire)
0-5 VDC (3-wire)
Ranges
Compound
-1 ... 10 bar
Wetted Parts Material
Stainless steel 316L (1.4404)
Ingress Protection
IP54
Stability
≤±0.25% span/year at reference conditions
Case or Body Material
Stainless steel 304 (1.4301)
Durability
>10 million cycles
Process Connection Style
1.125 ̋ Surface Mount (Type W and C)
Accuracy
1% of span
0.5% of span
Surface Finish
<0.18 μm Ra
Pressure Type
Gauge pressure